  1. SHOWSET & Related Files - (C) 1991 Micro Firmware Inc.
  2.  
  3. The ShowSet program, documentation, and related files may be freely
  4. distributed so long as all the files are distributed together and
  5. unmodified.
  6.  
  7. ShowSet is periodically updated, and the updates can always be
  8. obtained from the Micro Firmware Product Support BBS, which can be
  9. reached at the following numbers:
  10.  
  11. 300/1200/2400 BPS ........... 405-321-2616
  12. 300/1200/2400 BPS MNP ....... 405-321-2400
  13. 300/1200/2400/9600 V.32 ..... 405-321-3553
  14.  
  15. Connect with 8-bit word, one stop bit, and no parity.
  16.  
  17.             *******************************
  18.  
  19. As of version 1.60, ShowSet should be able to identify systems running
  20. standard implementations of the following chip sets:
  21.  
  22.     Acer
  23.     *       1207
  24.  
  25.     Chips & Technologies:
  26.     *       CS8221 (NEAT)
  27.     *       CS8230
  28.     *       82C235 (SCAT)
  29.  
  30.     Headland Technology:
  31.     *       HT113
  32.         HT21
  33.  
  34.     Intel:
  35.         82335
  36.  
  37.     OPTi:
  38.     *       HiD/386 or HiB/486
  39.         Cache Sx/AT
  40.         386WB
  41.  
  42.     Sun Electronics:
  43.     *       Suntac
  44.  
  45.     VLSI Technology:
  46.     *       VL82CPCAT-16/20 (enhanced)
  47.     *       VL82C286 (TopCat)
  48.         VL82C386 (TopCat)
  49.  
  50. Those marked with an asterisk ("*") have been verified as being correctly
  51. identified on an actual motherboard. The others are only based on information
  52. (sometimes preliminary) of how the chip set should behave and has not yet
  53. been verified against an actual implementation. I would appreciate any
  54. feedback on the results of running ShowSet on a computer using one of the
  55. currently unverified chip sets.
  56.  
  57.  
  58. 6/26/91
  59. Changes introduced in version 1.60:
  60.  
  61.     ShowSet now scans the system BIOS in an attempt to locate
  62.     a chip set name. This will help identify chip sets that
  63.     ShowSet does not currently know how to test for and/or
  64.     chip sets that might be otherwise undetectable (such as,
  65.     in some circumstances, Intel's 82335 chip set).
  66.  
  67. 3/5/91
  68. Changes introduced in version 1.50:
  69.  
  70.     The Acer 1207 and Chips & Technologies SCAT tests were added.
  71.  
  72. 1/24/91
  73. Changes introduced in version 1.42:
  74.  
  75.     In some implementations, due to a perculiarity in the address
  76.     decoding, VLSI Technology's VL82CPCAT-16/20 (enhanced) chip set
  77.     was not always recognized. This was corrected.
  78.  
  79. Changes introduced in version 1.41:
  80.  
  81.     The OPTi tests would identify Chips & Technologies chip sets
  82.     as an unknown OPTi. This was corrected.
  83.  
  84. Changes introduced in version 1.40:
  85.  
  86.     Tests for OPTi's chip sets were added.
  87.  
  88. Changes introduced in version 1.30:
  89.  
  90.     The Suntac test now leaves the EMS base port address in its
  91.     original locatation. Because of an oversight in changes made in
  92.     version 1.20, the EMS base port address would get moved to E8h
  93.     if the power-on location was 98h
  94.  
  95.     Tests for CS8220, VL82CPCAT-16/20, and VL82C386 were added.
  96.  
  97.     Internal organization was restructured and optimized somewhat.
  98.  
  99.     The architecture tests were made a bit more stringent. Some
  100.     XT semi-compatibles were being identified as being an XT.
  101.  
  102. Changes introduced in version 1.20: (initial release)
  103.  
  104.     Tests for machine architecture (PC, XT, AT, or other) were added.
  105.  
  106.     Tests for 82335 and VL82C286 were added
  107.  
  108.     The Suntac test was changed to deal with the EMS base port address
  109.     being at a non-default location.
  110.  
  111.     All tests were updated to deal with the data bus "floating". On
  112.     some motherboards it was found that reading from an undefined port
  113.     would return the last value transfered on the external data bus.